On the roof of the home there was a sheet metal system, with a sandwich panel, which presented several infiltration problems, traditional in this type of solution: problems of water infiltration in the gutters and in the connection of these to the roof sheets, weak finishes to the various elements existing in the roof. roofs, such as chimneys or stairwells and metal finishing helmets around the perimeter.
We apply a system composed of thermal insulation in polyisocyanurate and waterproofing Koster TPO 1.5, both mechanically fixed to the sheet. We eliminate gutters, metal perimeter helmets and waterproof all roof elements.
In addition to the thermal benefits, we have resulted in a system that, due to its quality and continuity, has a total waterproofing capacity that will last for many years.